OPERATING MANUAL INSTALLATION
Release 1.0 (98/07) 2-9
2.6.4 Current Mode Operation Check
1.
Ensure the front panel AC power switch is set to OFF.
2.
Turn the voltage and current controls on the front panel fully counter-clockwise.
3.
Connect the DC shunt across the output terminals on the rear panel.
4.
Connect the DVM across the DC shunt.
5.
Turn the AC power switch to ON.
6.
Turn the voltage control 1 or 2 turns clockwise.
7.
Turn the current control slowly clockwise.
8.
Compare the DVM reading with the front panel ammeter reading using I=V/R where I is the current, V
is the DVM reading, and R is the DC shunt resistance. The minimum control range is from zero to the
maximum rated output for the power supply model. The current mode LED turns on.
9.
Turn the AC power switch to OFF.
10.
Disconnect the DVM and the shunt.
2.6.5 Front Panel Function Checks
1.
Turn the front panel AC switch to ON.
2.
Set voltage and current controls fully clockwise. Push the STANDBY switch to its IN position and
check that the voltmeter reading falls to zero and the red S/D (Shutdown) LED turns on. Push the
STANDBY switch once again to reset it to its OUT position. The S/D LED turns off and the voltmeter
reading returns to its previous value.
3.
Press the STANDBY switch to its IN position.
4.
Press the OVP CHECK switch and check that the voltmeter displays approximately the model-rated
output voltage plus 10%.
5.
Turn the OVP SET potentiometer counter-clockwise and check that the voltmeter reading decreases.
Continued turning (up to 20 turns) will see the reading decrease to approximately 5% of the
model-rated voltage output. Turn the OVP SET potentiometer clockwise until the voltmeter once again
displays approximately the model-rated output voltage plus 10%.
6.
Press the STANDBY switch to its OUT position.
7.
Press the V/I CHECK switch and check that the voltmeter and ammeter display the power supply
output ratings.
8.
Turn the front panel AC power switch to OFF.
Note: You can use the front panel LOCAL button only when a digital programming interface has been